 17. Set the control valve at a specific stop. NOTE:
The valve has four adjustable stops for the flow
rate setting. To change the flow rate simply
relocate the setscrew stop. (Figure 2, page 8)
FLOW RATES
 18. Knob forward (OFF).
 19. First hole 1/4 flow rate turn counter clockwise.
 20. Second hole 1/2 flow rate turn counter- clockwise.
 21. Third hole
3
/
4
flow rate turn counter clockwise.
 22. Fourth hole full flow rate turn counter clock-wise.
 23. Spray for a specific time. The longer this time
period, the more accurate the calibration will be.
 24. Remove the remaining insecticide from the tank
and measure. The difference in the starting and
ending measurement will be the usage for the
specific time spraying took place.
MAINTENANCE
 25. Always flush out ULV sprayer with a recommended
flushing solvent. For "field" use, you may use
transmission fluid.